simrt (Anzai Medical Co Ltd)
Structured Review

Simrt, supplied by Anzai Medical Co Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/simrt/product/Anzai Medical Co Ltd
Average 90 stars, based on 1 article reviews
Images
1) Product Images from "Comparative evaluation of a surface‐based respiratory monitoring system against a pressure sensor for 4DCT image reconstruction in phantoms"
Article Title: Comparative evaluation of a surface‐based respiratory monitoring system against a pressure sensor for 4DCT image reconstruction in phantoms
Journal: Journal of Applied Clinical Medical Physics
doi: 10.1002/acm2.14174
Figure Legend Snippet: Experimental setup at the Somatom Confidence CT room (a) including the CIRS Phantom (b), sponge (c), Anzai belt (d), Anzai laptop (e), SimRT camera pod (f), reference capture with patch in grey (g), styrodur block in green including three imaging rods in pink (h), and the calibration plate (80 × 60) cm (i). CT, computed tomography; CIRS, Computerized Imaging Reference Systems.
Techniques Used: Blocking Assay, Imaging, Computed Tomography
Figure Legend Snippet: Six breathing patterns measured by Anzai and SimRT using the CIRS phantom compared with the ground‐truth. A = amplitude; C1 = cos 4 (A = 2 mm, without CT); C1* = cos 4 (A = 2 mm, during CT); C5 = cos 4 (A = 16 mm, without CT); C5* = cos 4 (A = 16 mm, during CT). CT, computed tomography; CIRS, Computerized Imaging Reference Systems; IRV, volunteer with irregular breathing pattern; MAD, mean absolute deviation; RV, volunteer with regular breathing pattern.
Techniques Used: Computed Tomography, Imaging
Figure Legend Snippet: Summary of real, tag peak‐to‐peak amplitudes and MADs between the ground‐truth and measurements recorded by SimRT and Anzai for all regular and irregular breathing patterns.
Techniques Used:
Figure Legend Snippet: Precision of tagging for peaks and valleys showing the time difference between real and tag values determined by the SimRT and Anzai algorithms for regular and irregular breathing patterns, respectively.
Techniques Used:
Figure Legend Snippet: Tumor trajectory inside the CIRS phantom in LR, IS, and AP directions using 10, 16, and 10 mm for the first experiment A (upper three diagrams) and 2 mm for the second B (lower three diagrams). Maximal SD was ±1.4 mm in AP, ±0.7 mm in IS, and ±0.3 mm in IS for Anzai, SimRT and Static, respectively. A sponge was used here as a surrogate. AP, anteroposterior; Ex, exhale; IS, inferior‐superior; In, inhale; Static, static 3DCT scan; LR, left‐right; SD, standard deviation.
Techniques Used: Standard Deviation
Figure Legend Snippet: Axial mid‐position sections of the 4DCT images reconstructed by using breathing patterns from both Anzai and SimRT compared to the static 3DCT.
Techniques Used: